Easy product returns
You can return the product without providing a reason within 14 days.
Milwaukee MC811 Combo Monitor pH / EC / temp
EXACT. STRAIGHT. RELIABLE. 24/7 PH / EC and TEMPERATURE MONITORING.
Why guard when you can monitor! The Milwaukee MC811 MAX pH / EC / Temp monitor allows you to automatically monitor pH / EC / Temp levels 24/7.
TEST COMMENTS
"I run this device 24/7 and from two months I had no problems. I can monitor 24/7, point the camera at it and connect to the phone. "
"Easy Calibration".
"Using this now is much cheaper than what my friends paid ... I recommend it to any serious breeder."
DESCRIPTION
The MC811 MAX monitor automatically monitors and displays pH / EC / Temp levels. Just calibrate the parameters and the Milwaukee MAX will do the rest.
The Milwaukee MC811 MAX pH / EC / Temp Monitor is the preferred choice for people who want to know their pH and nutrient levels 24/7. Typical applications are nutrient tanks, hydroponics and aquariums.
The Milwaukee MAX pH / EC / Temp monitor offers:
PRECISION
The Milwaukee MAX monitor is accurate to ± 0.2 pH with two point manual calibration, EC accuracy of ± 2% of full scale and temperature accuracy of ± 0.5 ° F (0.3 ° C).
AUTOMATION
Just calibrate the parameters and start monitoring 24/7! span>
EASY INSTALLATION
MC811 MAX pH / EC / Temp monitor comes with complete mounting kit, including probe holder.
DESIGN FEATURES
Quick and easy reading up-to-date results thanks to 3 large digital LCD readings with backlight.
Accuracy up to ± 0.2 pH (0.0 to 12.0 pH).
Exact ± 2% of full EC scale.
An external switch on top of the device converts the conductivity of the EC to EC using a conversion factor of 0.5 or 0.7.
Simple 2-point pH calibration and 1-point EC calibration for increased accuracy with manual trimmers for easy adjustment.
Gel-filled pH electrode with MA911B / 2 double junction (included) for laboratory, low maintenance and high performance.
Probe cables o 6.5 feet lengths provide extra flexibility when testing.
12 VDC power supply.
USE AND CARE
pH meters usually start to malfunction due to problems with probe. The two parts of the pH probe that cause problems are the glass bulb (sensor) and the reference junction.
FEELING THE BULB
The glass bubble loses sensitivity during use and will eventually fail. This applies to all pH probes.
REFERENCE NODE
A reference junction is a small hole that allows the gauge to compare a sample with pattern. The reading is generated from the electrical difference between sample and standard. If the connector hole becomes clogged, the pH probe will no longer function.
You can extend the life of the pH electrode in the following ways.
STORAGE
The pH probe must be hydrated. Long periods of dry storage will damage the probe sensitivity. Allowing the probe to dry may also clog the connector opening.
Storing in pH probe storage solution or pH calibration buffers will help overcome both of these problems. Do not store in tap and deionized water. This will damage the probe sensitivity.
The best way to store the probe is to fill the probe cap with storage solution or calibration bu